Cisco经典文档

当前位置: 首页Cisco经典文档Catalyst交换机电缆、连接器和AC电源线指 南_英文原版


Catalyst Switch Cable, Connector, and AC Power Cord Guide

            

 

                                                       文档下载:

切换至中文版


Contents

Introduction
Prerequisites
      Requirements
      Components Used
      Conventions
Console and Aux Port Cables
Which RJ-45 Ethernet Cable Do I Use?
      Cables to Hubs, Switches, Routers, and Workstations
Most Common Cable Connectors
GBIC and SFP Connectors
Catalyst 6500/6000 Switch Connectors and Cables
Catalyst 5500/5000 Connectors and Cables
Catalyst 4500/4000 Switch Connectors and Cables
Catalyst 3750 Connectors and Cables
Catalyst 3560/3560E Connectors and Cables
      SFP Module Patch Cable
Catalyst 3550 Connectors and Cables
Catalyst 2970 Connectors and Cables
Catalyst 2950/2955 Connectors and Cables
Catalyst 2940 Connectors and Cables
Catalyst 2900/3500 XL Connectors and Cables
AC Power Supplies, Connectors, and Cords for Catalyst Switches
      Catalyst 6500/6000 Series Switch Power Supplies and Cables
      Catalyst 5500/5000 Series Switch Power Supplies and Cables
      Catalyst 4500/4000 Series Switch Power Supplies and Cables
      Catalyst 2900/3500XL, 2940, 2950, 3550 and 3750 Series Switch Power Supplies and Cables
RJ-21 to RJ-45 Pin-Out Pattern


Introduction

This document is a guide to cables and connectors for Catalyst 6500/6000, 5500/5000, and 4500/4000 series switching modules and Catalyst 2900/3500 XL, 2940, 2970, 2950/2955, 3550, and 3750 series fixed-configuration switches. AC power supplies, connectors, and cords for these switches are also covered.

Prerequisites

Requirements

You should identify the part or model number of your switch/supervisor, switching module, or power supply in order to use this document effectively. Do this by visual inspection, or issue the show module command where possible.

Components Used

This document is not restricted to specific software and hardware versions.

Conventions

Refer to Cisco Technical Tips Conventions for more information on document conventions.

Console and Aux Port Cables

Different Catalyst Supervisor Engines use either a rolled or a straight-through cable in order to connect a terminal or modem to the console port. Refer to these documents for information on how to connect a terminal or modem to the console port of Catalyst series switches:

Auxiliary (AUX) ports on Layer 3 (L3) switches or modules behave much the same way as AUX ports on routers and are used to connect modems. Refer to Modem-Router Connection Guide for information on how to connect a modem to an AUX port.

Which RJ-45 Ethernet Cable Do I Use?

A common question that concerns RJ-45 unshielded twisted pair (UTP) Ethernet cable concerns how to distinguish between rolled, straight-through, and crossover cables, and when to use them. Use the comparison guide found in the Types of RJ-45 Cabling section of Cabling Guide for Console and AUX Ports in order to see the difference between these cables.

Cables to Hubs, Switches, Routers, and Workstations

Crossover and straight-through cables are used in order to connect switch ports or interfaces to network devices. Consult this table in order to see when to use each of these cable types. Find the device in the left-hand column and match it up with another device in the top row. The intersection of these two devices gives you the cable type used to connect them together.

 

Hub

Switch

Router

Workstation

Hub

Crossover

Crossover

Straight

Straight

Switch

Crossover

Crossover

Straight

Straight

Router

Straight

Straight

Crossover

Crossover

Workstation

Straight

Straight

Crossover

Crossover

 

Note: The ports on Catalyst switches that run Cisco IOS® Software (Native) can be configured to act as Layer 2 (L2) or Layer 3 (L3) ports. When you connect the RJ-45 cable from a Layer 3 port, which acts as a router port, to other devices, use the previous table. In summary, the cables used do not change, regardless of whether the port is configured to be in Layer 2 (switch port) or Layer 3 (router port) mode.

Most Common Cable Connectors

These diagrams show some of the most common cable types and connectors used on Catalyst switches.

RJ-45

RJ-21 Telco

132a.gif

132b.gif

This is used in order to connect to 10/100 or 10/100/1000 Ethernet ports and 1000Base-T Gigabit Interface Converter (GBIC) or small form factor pluggable (SFP) GBIC ports. 10/100/1000 Ethernet ports must use four twisted-pair Category 5, 5e or 6 cables.

This is used in order to connect to 10/100BASE-TX RJ-21 telco interfaces. Use Category 5 UTP cables with male RJ-21.

 

MT-RJ Fiber-Optic

SC Fiber-Optic

132c.gif

132d.gif

This is used in order to connect to 100Base-FX fiber-optic ports. Use multimode fiber (MMF) cables with MT-RJ connectors.

This is used in order to connect to 100Base-FX, 1000Base-SX, Long Wavelength/Long Haul (LX/LH) and ZX fiber-optic ports or GBICs. Use MMF or single-mode fiber (SMF) fiber-optic cable.

 

LC Fiber-Optic

GigaStack

132e.gif

132f.gif

132g.gif

This is used in order to connect to SFP fiber-optic module ports.

This is used in order to connect to GigaStack GBIC ports. Cisco GigaStack technology uses proprietary GBICs and cables.

 

StackWise

132h.gif

This is used in order to connect to StackWise ports on the rear panel of Catalyst 3750 switches.

Cisco StackWise technology uses proprietary connectors and cables.

 

GBIC and SFP Connectors

Many Catalyst switches, Supervisor Engines and switching modules have removable Gigabit Interface Converters (GBICs) or small form factor pluggable (SFP)-type connectors. These diagrams show some of the most common GBIC and SFP connectors used on Catalyst switches.

Note: A Catalyst 2950 switch is used for demonstration purposes.

1000Base-X

1000Base-T

132i.gif

132j.gif

This uses SC fiber-optic connector and MMF or SMF cable.

Part numbers: WS-G5484 (1000Base-SX GBIC) WS-G5486 (1000Base-LX/LH GBIC) WS-G5487 (1000Base-ZX GBIC)

This uses RJ-45 connector and cable.

Part number: WS-G5483 (1000Base-T GBIC)

 

WS-X3500-XL GigaStack GBIC

SFP Module

132k.gif

132l.gif

This uses Cisco Gigastack connector and cable.

Part Number: WS-X3500-XL (GigaStack GBIC)

This uses LC fiber-optic connector or RJ-45 for 1000Base-T SFP.

Part numbers: GLC-T (1000Base-T SFP) GLC-SX-MM (1000Base-SX SFP) GLC-LH-SM (1000Base-LX/LH SFP) GLC-ZX-SM (1000Base-ZX)

 

GBIC and SFP support depends on the platform and software version. Refer to these documents for GigabitEthernet system requirements, as well as GBIC system requirements, Coarse Wave Division Multiplexer (CWDM) GBIC, Gigastack GBIC, and SFP system requirements:

Catalyst 6500/6000 Switch Connectors and Cables

Identify the switch chassis and switching module part number. Use this table in order to match up the part number with the type of connector and cable used.

Note: This guide does not cover cables for the Catalyst 6000 Optical Services Module (OSM) or port adapter cables for the FlexWAN card.

Refer to Optical Services Module Installation and Verification Note for OSM cabling and specifications.

Refer to FlexWAN Module Port Adapter Install/Config Notes for FlexWAN port adapter cabling and specifications.

Switching Module Part Number

Connector Type

Cable Description

Cable/Connector Specifications

WS-X6148-RJ45V WS-X6248-RJ45 WS-X6348-RJ45 WS-X6348-RJ45V WS-X6548-RJ45  48 10/100 or 10/100 inline power Ethernet ports

WS-X6148-GE-TX WS-X6148V-GE-TX WS-X6548-GE-TX WS-X6548V-GE-TX 48 10/100/1000 or 10/100/1000 inline power Ethernet ports (1000Base-T)

WS-X6748-GE-TX 48 10/100/1000 Ethernet ports (used with Supervisor 720 only)

RJ-45 (for 10/100 and 1000Base-T ports)

Category 5, 5e, or 6 UTP

Catalyst 6500/6000 Hardware Guide

WS-X6516-GE-TX 16 10/100/1000 Base-T Gigabit Ethernet ports

RJ-45 (for 1000Base-T GBIC)

Category 5, 5e, or 6 UTP

WS-X6148-RJ21V WS-X6248-TEL WS-X6248A-TEL WS-X6348-RJ21V WS-X6548-RJ21 48 Port 10/100 Ethernet ports

RJ-21 telco (4 connectors)

Category 5 UTP cable

WS-X6024-10FL-MT 24 10Base-FL ports

WS-X6224-100FX-MT WS-X6324-100FX-MM WS-X6324-100FX-SM WS-X6524-100FX-MM 24 100Base-FX ports

MT-RJ fiber-optic

SMF/MMF fiber-optic

WS-X6416-GE-MT 16 100Base-FX Gigabit Ethernet ports (1000Mbps)

MT-RJ fiber-optic

MMF fiber-optic

WS-X6408-GBIC WS-X6408A-GBIC WS-X6416-GBIC WS-X6516-GBIC WS-X6516A-GBIC WS-X6816-GBIC 8 or 16 GBIC module slots

RJ-45 (for 1000Base-T GBIC)

Category 5, 5e, 6 UTP

SC fiber-optic 1 (1000BaseSX/LX/ZX and CWDM GBICs)

MMF fiber-optic

WS-X6501-10GEX4 1 port 10-Gigabit Ethernet

WS-X6502-10GE with Optical Interface Module (OIM) 1-port 10-Gigabit Ethernet

WS-X6704-10GE 4 port 10-Gigabit Ethernet (used with Supervisor 720 only)

SC fiber-optic

SMF or dispersion-shifted SMF fiber-optic

WS-X6724-SFP 24 SFP module slots (used with Supervisor 720 only)

RJ-45 (for 1000Base-T SFP)

Category 5, 5e, 6 UTP

LC fiber-optic (for 1000Base-SX/LX/ZX  SFPs)

SMF/MMF fiber-optic

 

1 LX/LH GBICs require a mode-conditioning patch cord between the GBIC and MMF. Refer to the Mode-Conditioning Patch Cord section of the document Connector and Cable Specifications for more information.

Catalyst 5500/5000 Connectors and Cables

Identify the switching module part number. Use this table in order to match up the part number with the type of connector and cable used.

Note: This guide does not cover Catalyst 5000 Fiber Distributed Data Interface (FDDI) and Copper Distributed Data Interface (CDDI) cables, Catalyst 5000 ATM cables, or Catalyst 5000 Token Ring cables. Refer to Installation Preparation for cabling and specifications for these modules.

Switching Module Part Number

Connector Type

Cable Description

Cable/Connector Specifications

WS-X5013 WS-X5014 24 or 48 10-Base-T Ethernet ports

WS-X5113 WS-X5223 12 or 24 100Base-TX Ethernet ports

WS-X5203 WS-X5213A 12 10/100 Ethernet ports

WS-X5224 WS-X5225R WS-X5234-RJ45J45 24 10/100 Ethernet ports

RJ-45

Category 3 or 5 UTP cable 1

Catalyst 5000 Hardware Guide

WS-X5012 WS-X5012A WS-X5020 48 Port 10Base-T Ethernet ports

WS-X5239-RJ21 48 10/100 Ethernet ports

RJ-21 telco

Category 3 or 5 UTP cable 1

WS-X5015-MT 24 10Base-FL ports

WS-X5236-FX-MT WS-X5237-FX-MT 24 100Base-FX

MT-RJ fiber-optic

SMF/MMF fiber-optic

WS-X5114 WS-X5201 WS-X5201R 12 100Base-FX ports

SC fiber-optic (for 100Base-FX)

SMF/MMF fiber-optic

WS-X5403 3 port GBIC modules slots

WS-X5410 9 GBIC module slots

SC fiber-optic (for 1000BaseSX/LX/ZX GBICs)

SMF/MMF 2 fiber-optic

 

1 Category 3 UTP cable can transmit data at speeds of up to 10 Mbps and therefore is only used for 10 Mbps network devices. Catalyst 5000 10Base-T telco switching modules can use Category 3 cable, but Category 5 cable is required for all other 10/100 Base-TX switching modules.

2 LX/LH GBICs require a mode-conditioning patch cord between the GBIC and MMF. Refer to the Mode-Conditioning Patch Cord section of the document Connector and Cable Specifications for more information.

Catalyst 4500/4000 Switch Connectors and Cables

Refer to Catalyst 4500 Series Module Installation Guide - Module Overview and Specifications for the detailed specification for the Catalyst 4500 switching modules.

Refer to Catalyst 4000 Switching Modules for the detailed specification for the Catalyst 4000 switching modules.

Catalyst 3750 Connectors and Cables

Identify the switch chassis part number. Use this table in order to match up the part number with the type of connector and cable used.

Note: The Catalyst 3750 switch ships with a 0.5-meter StackWise cable that you can use in order to connect the StackWise ports on the rear panel. You can also order these StackWise cables from your Cisco sales representative:

  • CAB-STACK-50CM= (0.5-meter cable)

  • CAB-STACK-1M= (1-meter cable)

  • CAB-STACK-3M= (3-meter cable)

Part Number

Connector Type

Cable Type

Cable/Connector Specifications

WS-C3750-24TS WS-C3750-48TS 24 or 48 10/100 Ethernet ports and 2 or 4 SFP module slots

RJ-45 (for 10/100 ports)

Category 5, 5e, or 6 UTP cable

Catalyst 3750 Hardware Guide

SFP: LC fiber-optic (for 1000Base-SX/LX) or RJ-45 (for 1000Base-T)

SFP: SMF/MMF fiber-optic, or Cat5, 5e, or 6

WS-C3750G-24TS 24 10/100/1000 and  4 SFP module slots

RJ-45 (for 10/100/1000 ports)

Category 5, 5e, or 6 UTP cable

SFP: LC fiber-optic (for 1000Base-SX/LX) or RJ-45 (for 1000Base-T)

SFP: SMF/MMF fiber-optic, or Cat5, 5e, or 6

WS-C3750G-24T 24 10/100/1000 Ethernet ports

RJ-45

Category 5, 5e, or 6 UTP cable

WS-C3750G-12S 12 SFP module slots

SFP: LC fiber-optic (for 1000Base-SX/LX) or RJ-45 (for 1000Base-T)

SFP: SMF/MMF fiber-optic, or Cat5, 5e, or 6

 

Catalyst 3560/3560E Connectors and Cables

Identify the switch chassis part number. Use this table in order to match up the part number with the type of connector and cable used.

Part Number

Connector Type

Cable Type

Cable/Connector Specifications

WS-C3560-8PC

RJ-45 (10/100)

Two pair Cat 5, 5e, or 6 UTP

Catalyst 3560 Hardware Guide

Also refer to Cisco Small Form-Factor Pluggable (SFP) Transceiver Modules Maintenance and Troubleshooting.

RJ-45 (10/100/1000)

Four pair Cat 5, 5e, or 6 UTP

SFP (100Base-FX/LX/BX)

LC Fiber-optic SMF/MMF

WS-C3560-24TS, WS-C3560-48TS, WS-C3560-24PS, WS-C3560-48PS

RJ-45 (10/100)

SFP (1000Base-T)

Two pair Cat 5, 5e, or 6 UTP

SFP (1000Base-LH/SX/ZX)

LC Fiber-optic SMF/MMF

WS-C3560G-24TS, WS-C3560G-48TS, WS-C3560G-24PS, WS-C3560G-48PS

RJ-45 (10/100/1000)

SFP (1000Base-T)

Four pair Cat 5, 5e, or 6 UTP

SFP (1000Base-LH/SX/ZX)

LC Fiber-optic SMF/MMF

WS-C3560E-24TD, WS-C3560E-24PD, WS-C3560E-48TD, WS-C3560E-48PD, WS-C3560E-48PD-F

RJ-45 (10/100/1000)

SFP (1000Base-T)

Four pair Cat 5, 5e, or 6 UTP

SFP (100Base-FX, 1000Base-LH/SX/ZX)

LC Fiber-optic SMF/MMF

X2 Based (10GBASE-SR/LR/ER)

SC Fiber-optic SMF/MMF

 

SFP Module Patch Cable

The Catalyst 3560 switch supports the SFP module patch cable, a 1/2 meter, copper, passive cable with SFP module connectors at each end. The patch cable can connect two Catalyst 3560 switches in a cascaded configuration.

Part Number

Description

CAB-SFP-50CM=

Cisco Catalyst 3560 SFP Interconnect Cable (50 dcm)

 

132v.gif

Catalyst 3550 Connectors and Cables

Identify the switch chassis part number. Use this table in order to match up the part number with the type of connector and cable used.

Note: Some Catalyst 3550 switches support the GigaStack GBIC, which requires a Cisco proprietary cable of either CAB-GS-50CM (0.5-meter cable) or CAB-GS-1M (1-meter cable).

Part Number

Connector Type

Cable Type

Cable/Connector Specifications

WS-C3550-12T 10 10/100/1000 Ethernet ports and 2 GBIC module slots

WS-C3550-12G 2 10/100/1000 Ethernet ports and 10 GBIC module slots

WS-C3550-24-SMI, WS-C3550-24-DC-SMI WS-C3550-48-SMI WS-C3550-24-EMI WS-C3550-48-EMI 24 or 48 10/100 Ethernet ports and 2 GBIC module slots

WS-C3550-24PWR-SMI WS-C3550-24PWR-EMI 2410/100 inline-power Ethernet ports and 2 GBIC module slots

RJ-45 (for 10/100 or 10/100 inline power or 10/100/1000 ports)

Category 5, 5e, 6 UTP

Catalyst 3550 Hardware Guide

GBIC: RJ-45 for 1000Base-T GBIC or SC fiber-optic (for 1000Base-SX/LX/ZX and CWDM GBICs) or Gigastack GBIC

GBIC: Cat 5, 5e, 6 UTP or MMF/SMF fiber-optic or GigaStack cable

WS-C3550-24-FX-SMI 24 100Base-FX ports and 2 GBIC module slots

MT-RJ fiber-optic (for 100Base-FX ports)

MMF fiber-optic

GBIC: RJ-45 for 1000Base-T GBIC or SC fiber-optic (for 1000Base-SX/LX/ZX and CWDM GBICs) or Gigastack GBIC

GBIC: Cat 5, 5e, 6 UTP or MMF/SMF fiber-optic or GigaStack cable

 

Catalyst 2970 Connectors and Cables

Part Number

Connector Type

Cable Type

Cable/Connector Specifications

WS-C2970G-24T 24 10/100/1000 Ethernet

RJ-45

Category 5, 5e, or 6 UTP

Catalyst 2970 Hardware Guide

WS-C2970G-24TS 24 10/100/1000 and  4 SFP module slots

RJ-45 (for 10/100/1000 ports)

Category 5, 5e, or 6 UTP

SFP: RJ-45 (for 1000Base-T) or LC fiber-optic (for 1000Base-SX/LX/ZX)

SFP: Cat5, 5e, or 6 UTP or SMF/MMF fiber-optic

 

Catalyst 2950/2955 Connectors and Cables

Identify the switch chassis part number. Use this table in order to match up the part number with the type of connector and cable used.

Note: This guide does not cover the Catalyst 2950 Long-Reach Ethernet (LRE) Switches. Refer to Long-Reach Ethernet Products for more information on cabling and specifications.

Note: Some Catalyst 2950 switches support the GigaStack GBIC, which requires a Cisco proprietary cable of either CAB-GS-50CM (0.5-meter cable) or CAB-GS-1M (1-meter cable).

Part Number

Connector Type

Cable Type

Cable/Connector Specifications

WS-C2950-12 and WS-C2950-24 12 or 24 10/100 Ethernet ports

RJ-45

Category 5, 5e, or 6 UTP cable

Catalyst 2950 Hardware Guide

Catalyst 2955 Hardware Guide

WS-C2955C-12 and WS-C2950C-24 12 or 24 10/100 Ethernet ports and 2 100BASE-FX ports

RJ-45 (for 10/100 ports)

Category 5, 5e, or 6 UTP cable

MT-RJ fiber-optic

MMF fiber-optic

WS-C2950G-12-EI, WS-C2950G-24-EI, WS-C2950G-24-EI-DC, and WS-C2950G-48-EI 12, 24, or 48 10/100 Ethernet ports and 2 GBIC module slots

RJ-45 (for 10/100 ports)

Category 5, 5e, or 6 UTP

GBIC: RJ-45 for 1000Base-T GBIC or SC fiber-optic (for 1000Base-SX/LX/ZX and CWDM GBICs) or Gigastack GBIC

GBIC: Cat 5, 5e, 6 UTP or MMF/SMF fiber-optic or GigaStack cable

WS-C2950SX-24 and WS-C2950SX-48-SI 24 or 48 10/100 Ethernet ports and 2 1000BASE-SX ports

RJ-45 (for 10/100 ports)

Category 5, 5e, or 6 UTP

MT-RJ fiber-optic (for 1000BASE-SX ports)

MMF/SMF fiber-optic

WS-C2955T-12 WS-C2950T-24 WS-C2950T-48-SI 12, 24 or 48 10/100 Ethernet ports and 2 10/100/1000 Ethernet ports

RJ-45

Category 5, 5e, or 6 UTP cable

WS-C2955S-12 12 10/100 Ethernet ports and 2 100Base-LX ports

RJ-45 (for 10/100 ports)

Category 5, 5e, or 6 UTP

MT-RJ fiber-optic

SMF fiber-optic

 

Catalyst 2940 Connectors and Cables

Identify the switch chassis part number. Use this table in order to match up the part number with the type of connector and cable used.

Part Number

Connector Type

Cable Type

Cable/Connector Specifications

WS-C2940-8TT-S 8 10/100 Ethernet ports and 1 10/100/1000 port

RJ-45

Category 5, 5e, or 6 UTP

Catalyst 2940 Hardware Guide

WS-C2940-8TF-S 8 10/100 Ethernet ports, 1 100BASE-FX port, and 1 SFP module slot

RJ-45

Category 5, 5e, or 6 UTP

MT-RJ fiber-optic

MMF fiber-optic

SFP: RJ-45 (for 1000Base-T) or LC fiber-optic (for 1000Base-X)

SFP: Cat5, 5e, or 6 UTP or SMF/MMF fiber-optic

 

Catalyst 2900/3500 XL Connectors and Cables

Identify the switch chassis or expansion module part number. Use this table in order to match up the part number with the type of connector and cable used.

Note: This guide does not cover the WS-C2912-LRE-XL or WS-C2912-LRE-XL switches. Refer to the Long-Range Ethernet Ports section of Product Overview (Catalyst 2900 Series XL switches) for more information on cabling and specifications.

Note: Some Catalyst 3500XL switches support the GigaStack GBIC, which requires a Cisco proprietary cable of either CAB-GS-50CM or CAB-GS-1M.

Catalyst 2900/3500XL Switches

Switch Chassis Part Number

Connector Type

Cable Description

Cable/Connector Specifications

WS-C3508G-XL 8 GBIC module slots

SC fiber-optic (for 1000Base-SX/LX/ZX GBICs) or Gigastack GBIC

MMF/SMF fiber-optic

Catalyst 3500XL Hardware Guide

Catalyst 2900XL Hardware Guide

WS-C3512-XL WS-C3524-XL WS-C3524-PWR-XL WS-C3548-XL 12, 24 or 48 10/100 or 10/100 inline power Ethernet ports and 2 GBIC module slots

RJ-45 (for 10/100 ports)

Category 5 UTP

GBIC: SC fiber-optic (for 1000Base-SX/LX/ZX GBICs) or Gigastack GBIC

GBIC: MMF/SMF fiber-optic or GigaStack cable

WS-C2912-XL WS-C2924-XL 12 or 24 10/100 Ethernet ports

RJ-45

Category 5 UTP

WS-C2924C-XL 22 10/100 Ethernet ports and 2 100Base-FX ports

SC fiber-optic (for 100Base-FX ports)

MMF fiber-optic

Catalyst 2900XL Switches with Expansion Slots

Switch Chassis Part Number

Connector Type

Cable Description

Cable/Connector Specifications

WS-C2924M-XL 24 10/100 Ethernet ports and 2 expansion slots

RJ-45

Category 5 UTP

Catalyst 2900XL Hardware Guide

WS-C2912MF-XL 12 100Base-FX ports and 2 expansion slots

SC fiber-optic (for 100Base-FX ports)

MMF fiber-optic

Catalyst 2900XL Expansion Modules

Switch Chassis Part Number

Connector Type

Cable Description

Cable/Connector Specifications

WS-X2914-XL WS-X2914-XL-V 4 10/100 Ethernet ports

WS-X2922-XL 2 10/100 Ethernet ports

RJ-45

Category 5 UTP

Catalyst 2900XL Hardware Guide

WS-X2922-XL-V 2 100Base-FX ports

WS-X2924-XL-V 4 100Base-FX ports

SC fiber-optic (for 100 Base-FX)

MMF fiber-optic

WS-X2931-XL 1 GBIC module slot

SC fiber-optic (for SX/LX GBICs)

MMF fiber-optic

WS-X2932-XL 1 GBIC module slot

RJ-45 (for 1000Base-T GBIC)

 

WS-X2951-XL 1 ATM-OC-3

RJ-45  (for ATM-OC-3)

Category 5 UTP

WS-X2961-XL 1 ATM-OC-3

SC fiber-optic (for ATM-OC-3)

MMF fiber-optic

WS-X2971-XL WS-X2972-XL 1 ATM-OC-3

SC fiber-optic (for ATM-OC-3)

SMF fiber-optic

 

AC Power Supplies, Connectors, and Cords for Catalyst Switches

In this section you see the summary of AC power supplies, power connectors, and cords for Catalyst 6500/6000, 5500/5000 and 4500/4000 series, and Catalyst 3750, 2950, 2940, and 2900/3500XL series switches. Refer to the Power Installation Guidelines in the tables that correspond in the next section for international power requirements, DC power requirements, and other technical specifications.

Different Modules require different amount of power. Inline Power modules supplies the power to the IP phones. Cisco has inline power module to power the IP phones. You have to choose the correct power supply in order to support the various line cards, modules and Supervisor Engines on the switch. Cisco offers a tool called the Cisco Power calculator which can be used in order to choose the correct power supply for your switch. Launch the Cisco Power calculator and fill out the Product family, Supervisor Engine, Input voltage, line cards and the number of PoE devices. IP phones are the example for PoE devices and most of the IP phones belong to IEEE 802.3af Device - Class 2 (7W). Then the power calculator shows the results of different choices of Power Supplies. From that you can choose the required power supply. The power supplies successfully operate at their greatest capacity if the input voltage is between 200 and 240 volts AC.

Catalyst 6500/6000 Series Switch Power Supplies and Cables

This table is a quick reference for the available power supplies and cables in North American standard. Refer to Catalyst 6500 Power supply specifications for the detailed specifications you can. These few points are important to know:

  • The 950W (PWR-950-AC), 950W DC (PWR-950-DC) and 1400W AC (PWR-1400-AC) are used only with the Catalyst 6503 and Catalyst 6503-E Switches.

  • The Power supplies 1000W and 1300W can be used only with Catalyst 6506, 6509, and 6509-NEB-A switches. The Supervisor Engines SUP32 and SUP720 are incompatible when 1000W and 1300W power supplies are used.

  • With a fully populated Catalyst 6513 switch, two 2500 W power supplies are not fully redundant.

  • If you operate the 2500 W power supply at the low range input (100 to 120 VAC), it is not redundant in a fully populated Catalyst 6509, Catalyst 6509-E, Catalyst 6509-NEB, or Catalyst 6509-NEB-A switch.

  • The Power supplies 2500W, 2700W, and 3000W can operate at two different voltage levels (110Vac and 220Vac). The Power supply output depends on the supplied input AC power. This table shows the power ouput:

    Power Supply

    Power Output at 110Vac, 16A

    Power Output at 220Vac, 16A

    2500W

    1300W

    2500W

    2700W

    1350W

    2700W

    3000W

    1400W

    3000W

     

  • The AC power cords are hardwired to the 4000W Power supplies (WS-CAC-4000W-US=). It supports only NEMA L6-30.

  • The 6000W power supply cannot be installed in the Catalyst 6503, Catalyst 6503-E, and Catalyst 6504-E switch chassis.

  • When 6000W power supply is used with the chassis Catalyst 6506, 6509, 6509-NEB, and 6509-NEB-A, it operates at 4000W maximum output. It operates at 6000W maximum output when it is used with Catalyst 6506-E, 6509-E, and 6513.

  • 6000W power supply has two AC Power inputs. These are the various combinations of AC inputs and the corresponding net power output:

    6000W Power Supply Power Options

    AC Input 1

    AC Input 2

    Net Power Supply Output

    110Vac, 16A

    Not Connected

    No Power Output

    Not Connected

    110Vac, 16A

    No Power Output

    110Vac, 16A

    110Vac, 16A

    2900W

    220Vac, 16A

    Not Connected

    2900W

    Not Connected

    220Vac, 16A

    2900W

    110Vac, 16A

    220Vac, 16A

    2900W

    220Vac, 16A

    110Vac, 16A

    2900W

    220Vac, 16A

    220Vac, 16A

    6000W

     

    Note: If you have 110Vac power inputs, you have to connect both the AC inputs of the 6000W power supply in order to power on the switch.

  • The Catalyst 6500 series switches allow you to mix AC-input and DC-input power supplies in the same chassis.

The modules have different power requirements, and some configurations require more power than a single power supply can provide. The power management feature allows you to power all installed modules with two power supplies. But, redundancy is not supported in this configuration because the total power drawn from both power supplies is at no time greater than the capability of one supply. Refer the Power Management and Environmental Monitoring of the Catalyst 6500 Software Configuration Guide for the detailed explanation of Power redundancy.

Note: This document does not discuss the total power available with the currently shipped power supplies for Catalyst 6500/6000 series switches or the amount drawn from each Catalyst 6500/6000 series line card. Refer to the document Power Management for Catalyst 6000 Series Switches for this information.

Catalyst 6500/6000

Power Supply Part Number

Power Cord Part Number

Connector Type

Power Installation Guidelines

PWR-950-AC 950W power supply

WS-CAC-1000W 1000W power supply

CAB-7KAC-15 AC Power Cord North America, 15A

132m.gif

Catalyst 6500/6000

WS-CAC-1300W 1300W Power Supply 

CAB-7513AC AC Power Cord North America (110Vac, 20A)

132n.gif

PWR-1400-AC 1400W Power Supply

CAB-7513AC= AC Power Cord North America (110Vac, 20A)

132n.gif

CAB-AC-2500W-US1= 250Vac 16A, straight-blade NEMA 6-20 plug

132o.gif

CAB-AC-C6K-TWLK= 250Vac 16A, twist-lock NEMA L6-20 plug

132p.gif

WS-CAC-2500W 2500W AC Power Supply 

CAB-7513AC AC Power Cord North America (110Vac, 20A)

132n.gif

CAB-AC-2500W-US1 250Vac 16A, straight-blade NEMA 6-20 plug

132o.gif

CAB-AC-C6K-TWLK 250Vac 16A, twist-lock NEMA L6-20 plug

132p.gif

PWR-2700-AC/4 2700W AC Power Supply 

CAB-7513AC AC Power Cord North America (110Vac, 20A)

132n.gif

 

CAB-AC-2500W-US1 250Vac 16A, straight-blade NEMA 6-20 plug

132o.gif

 

CAB-AC-C6K-TWLK 250Vac 16A, twist-lock NEMA L6-20 plug

132p.gif

WS-CAC-3000W 3000 W AC-input power supply

CAB-7513AC= 110Vac 20A, NEMA 5-20 plug

132n.gif

CAB-AC-2500W-US1= 250Vac 16A, straight-blade NEMA 6-20 plug

132o.gif

CAB-AC-C6K-TWLK= 250Vac 16A, twist-lock NEMA L6-20 plug

132p.gif

WS-CAC-4000W-US 4000W AC Power Supply

Cable-attached to the power supply 250Vac 30A

132q.gif

WS-CAC-6000W 6000W AC Power supply

CAB-7513AC= 110Vac 20A, NEMA 5-20 plug

132n.gif

CAB-AC-2500W-US1= 250Vac 16A, straight-blade NEMA 6-20 plug

132o.gif

CAB-AC-C6K-TWLK= 250Vac 16A, twist-lock NEMA L6-20 plug

132p.gif

 

Catalyst 5500/5000 Series Switch Power Supplies and Cables

This table has a quick reference for the available power supplies and the Power cord part number.

Catalyst 5002, 5505, 5500, and 5509

Power Supply Part Number

Power Cord Part Number

Connector Type

Power Installation Guidelines

WS-C5008B (Catalyst 5002 and 5505)

CAB-7KAC

132r.gif

Catalyst 5500/5000

WS-C5508 (Catalyst 5500)

CAB-7513AC

132n.gif

WS-C5518 (Catalyst 5509)

CAB-7KAC

132r.gif

CAB-7513AC

132n.gif

 

Catalyst 4500/4000 Series Switch Power Supplies and Cables

Refer to the Power Connection Guidelines for AC-Powered Systems section in Catalyst 4500 Series Hardware Installation Guide - Preparing for Installation for the list of Power supplies, cables and the corresponding part numbers.

Refer to Catalyst 4000 Series Installation Guide - Site Planning for the list of Catalyst 4000 Power supplies, cables and the corresponding part numbers.

Catalyst 2900/3500XL, 2940, 2950, 3550 and 3750 Series Switch Power Supplies and Cables

Catalyst 2900/3500, 2940, 2950, 3550 and 3750 switches require standard 110V, 15 Amp AC input Power. Refer to these Hardware Installation Guides for the detailed power specifications:

Catalyst 2900/3500XL, 2940, 2950, 3550 and 3750

Power Supply Part Number

Power Cord Part Number

Connector Type

Power Installation Guidelines

Internal non-replaceable AC power supply

CAB-AC=

132m.gif

N/A

 

RJ-21 to RJ-45 Pin-Out Pattern

All Catalyst family 10/100TX telco switching modules incorporate industry-standard RJ-21 connectors and require compatible Category 5 cabling systems to achieve 100 Mbps data rates.

Category 5 telco cables can be ordered directly from Cisco. Refer to Cisco.com for ordering information. This is the information on Cisco part numbers.

Model Number

Description

CAB-5-M180M120-10=

CAB-5-M180M120-5=

10 foot, male 180 degree to male 120 degree, Category 5 telco cable

5 foot, male 180 degree to male 120 degree, Category 5 telco cable

CAB-5-M120M120-10=

CAB-5-M120M120-5=

10 foot, male 120 degree to male 120 degree, Category 5 telco cable

5 foot, male 120 degree to male 120 degree, Category 5 telco cable

CAB-5-M120HYD-10=

CAB-5-M120HYD-5=

10 foot, male 120 degree to (12) RJ-45s, Category 5 telco cable

5 foot, male 120 degree to (12) RJ-45s, Category 5 telco cable

 

This table shows the pin-out pattern used on Catalyst 10/100TX (and 10BaseT) RJ-21 switching modules.

RJ-21 Pin Number

Wire Color

RJ-45 Pin Number

Port Number

26

White/Blue

1

1

1

Blue/White

2

 

27

White/Orange

3

 

2

Orange/White

6

 

28

White/Green

1

2

3

Green/White

2

 

29

White/Brown

3

 

4

Brown/White

6

 

30

White/Slate

1

3

5

Slate/White

2

 

31

Red/Blue

3

 

6

Blue/Red

6

 

32

Red/Orange

1

4

7

Orange/Red

2

 

33

Red/Green

3

 

8

Green/Red

6

 

34

Red/Brown

1

5

9

Brown/Red

2

 

35

Red/Slate

3

 

10

Slate/Red

6

 

36

Black/Blue

1

6

11

Blue/Black

2

 

37

Black/Orange

3

 

12

Orange/Black

6

 

38

Black/Green

1

7

13

Green/Black

2

 

39

Black/Brown

3

 

14

Brown/Black

6

 

40

Black/Slate

1

8

15

Slate/Black

2

 

41

Yellow/Blue

3

 

16

Blue/Yellow

6

 

42

Yellow/Orange

1

9

17

Orange/Yellow

2

 

43

Yellow/Green

3

 

18

Green/Yellow

6

 

44

Yellow/Brown

1

10

19

Brown/Yellow

2

 

45

Yellow/Slate

3

 

20

Slate/Yellow

6

 

46

Violet/Blue

1

11

21

Blue/Violet

2

 

47

Violet/Orange

3

 

22

Orange/Violet

6

 

48

Violet/Green

1

12

23

Green/Violet

2

 

49

Violet/Brown

3

 

24

Brown/Violet

6

 

50

Violet/Slate

NA

NA

25

Slate/Violet

NA

NA


 

 

注:本人能力有限,如遇不足之处,还请指正!

China-CCIE  QQ交流群:106155045   点击与作者QQ交谈